Direct Page Indirect Long Addressing is supported by eight instructions:
- ADC (opcode 67)
- AND (opcode 27)
- CMP (opcode C7)
- EOR (opcode 47)
- LDA (opcode A7)
- ORA (opcode 07)
- SBC (opcode E7)
- STA (opcode 87)
See Also
References
- Eyes & Lichty page 394, https://archive.org/details/0893037893ProgrammingThe65816/page/n420
- section 3.5.15 of 65c816 datasheet, https://westerndesigncenter.com/wdc/documentation/w65c816s.pdf