Basic Info | |||||||
---|---|---|---|---|---|---|---|
Addressing Mode | Opcode | Length | Speed | ||||
Immediate | C2 | 2 bytes | 3 cycles |
Flags Affected | ||||||||
---|---|---|---|---|---|---|---|---|
N | V | M | X | D | I | Z | C | |
emulation mode | N | V | . | . | D | I | Z | C |
native mode | N | V | M | X | D | I | Z | C |
REP (Reset Status Bits) is a 65c816 instruction that clears bits in the status register that correspond to set bits in the operand.
REP is the only way to clear the m and x flags directly (but PLP and RTI may clear them too.)[1] But, REP can't modify those two flags in emulation mode because they are being forced to be set.
Syntax
REP #nvmxdizc
See Also
References
- Eyes & Lichty page 489, on REP: https://archive.org/details/0893037893ProgrammingThe65816/page/489
- Labiak, page 173 on REP
- snes9x implementation of REP: https://github.com/snes9xgit/snes9x/blob/master/cpuops.cpp#L3145
- undisbeliever on REP: https://undisbeliever.net/snesdev/65816-opcodes.html#rep-reset-status-bits